hi SV-EC, I've uploaded revised proposals for 1707 (streaming concatenation operator) and 1715 (clocking block name to be useable as a read-only event). Changes to 1707 are minor, and attempt to reflect feedback from the last EC meeting. There remain, though, the concerns that I raised when I posted the previous proposal; see http://www.eda-stds.org/sv-ec/hm/4487.html Note also that I believe the current proposals for 1707 also answer the concerns in 1526. Changes to 1715 are more drastic, since the last meeting's consensus was that not inly should clockings have a .triggered property, they should also be able to act as first-class events so that they could be copied to event handles, passed through ports and so on. Please be aware that I'm neither a compiler writer nor an expert on language design, so my naive efforts may not necessarily hit the important issues. Criticisms and corrections welcomed. -- Jonathan Bromley, Consultant DOULOS - Developing Design Know-how VHDL * Verilog * SystemC * e * Perl * Tcl/Tk * Project Services Doulos Ltd. Church Hatch, 22 Market Place, Ringwood, Hampshire, BH24 1AW, UK Tel: +44 (0)1425 471223 Email: jonathan.bromley@doulos.com Fax: +44 (0)1425 471573 Web: http://www.doulos.com The contents of this message may contain personal views which are not the views of Doulos Ltd., unless specifically stated. -- This message has been scanned for viruses and dangerous content by MailScanner, and is believed to be clean.Received on Sat Jul 14 12:34:46 2007
This archive was generated by hypermail 2.1.8 : Sat Jul 14 2007 - 12:35:17 PDT