Subject: [sv-ec] Action item AI-28
From: Arturo Salz (Arturo.Salz@synopsys.com)
Date: Wed Mar 12 2003 - 10:05:28 PST
MessageGreetings,
I have an action item to clarify how clocking domain drives can be used in design code (AI-28). This was formerly section 14.4 and is now 13.14.
The answer is: Clocking domain can be used freely in design code. The semantics of a signal drive is identical to a non-blocking assignment (the syntax also reflects that).
Arturo